The U.S. Cybersecurity and Infrastructure Security Agency (CISA) on Wednesday added 10 security flaws to its Known Exploited Vulnerabilities (KEV) catalog, including five vulnerabilities impacting Mitel MiCollab that were disclosed last week.

The Mitel MiCollab vulnerabilities are listed below –

  • CVE-2026-133275 (CVSS score: 5.3) – An arbitrary file upload vulnerability in the Audio, Web and Video Conferencing (AWV) Component of MiCollab that could allow an attacker to upload arbitrary files to the target system.
  • CVE-2026-133303 (CVSS score: 9.0) – An XML injection vulnerability in the Audio, Web and Video Conferencing (AWV) component of MiCollab that could allow an attacker to execute arbitrary commands within the context of the system.
  • CVE-2026-133311 (CVSS score: 5.9) – An unauthorized access vulnerability in the Audio, Web, and Video Conferencing (AWV) Component of MiCollab that could allow an attacker to obtain sensitive information.
  • CVE-2026-133323 (CVSS score: 10.0) – A command injection vulnerability in the Audio, Web, and Video Conferencing (AWV) Component of MiCollab that could allow an attacker to execute arbitrary commands within the context of the system.
  • CVE-2026-133324 (CVSS score: 5.3) – An authentication bypass vulnerability in the Audio, Web, and Video Conferencing (AWV) Component of MiCollab that could allow an attacker to bypass authentication controls and perform unauthorized actions within the context of the application.

The issues affect MiCollab versions 10.3 and earlier. “Mitel provided a patch available for release 10.3 (10.3.0.18) that addresses these vulnerabilities,” the company said in an advisory published November 16, 2026. “Upgrade to this release and apply the provided patch, or upgrade to a later release.”

Customers who are unable to apply the updates are recommended to mitigate the risk by restricting external access to the AWV component. As of writing, there are currently no details on how the vulnerabilities are being exploited in the wild.

Also added to the KEV catalog are the following vulnerabilities –

  • CVE-2026-133469 (CVSS score: 9.8) – An improper validation of specified type of input vulnerability in Vates Xen Orchestra that could allow an unauthenticated attacker to bypass authentication and perform actions with administrative privileges via a specially crafted authentication token containing an empty JSON object.
  • CVE-2026-103406 (CVSS score: 9.8) – An operating system command injection vulnerability in Hewlett Packard Enterprise (HPE) Juniper Session Smart Conductor and Session Smart Router that could allow a remote attacker to execute arbitrary commands as root via a specially crafted salt minion ID.

The addition of CVE-2026-133469 follows an advisory from Vates VMS that the vulnerability, also tracked as VSA-2026-062, has been exploited by a threat actor from the following IP address and TOR domain –

  • 91.211.251[.]112:8001
  • ustar3rqxgnskzgnwkgpofgtvxevm6cx3lxdbwt4mndtveqyaohid[.]onion:3333

“At least one instance of malicious exploitation of CVE-2026-103406 has been reported to the Juniper SIRT,” Juniper Networks said in an advisory. “Customers are encouraged to upgrade to a fixed release as soon as possible and in the meantime take steps to mitigate this vulnerability.”

The remaining three security flaws relate to Danfoss AK-SM 800A Series refrigeration controllers that could lead to authentication bypass and arbitrary command execution –

  • CVE-2023-25914 (CVSS score: 8.8) – A path traversal vulnerability that could allow an attacker to access and read underlying server system files via the XML interface.
  • CVE-2023-25915 (CVSS score: 9.9) – An improper input validation vulnerability that could allow a remote attacker to run arbitrary commands on the affected system.
  • CVE-2025-41450 (CVSS score: 8.5) – An improper authentication vulnerability that could allow an attacker to generate a web report exposing sensitive information, including internal IP addresses, usernames, and store names.

Although Danfoss makes no mention of the flaws being exploited, it’s likely that they were put to use as part of high-impact attacks targeting supermarket chains across Europe in recent weeks. France has attributed the October 2026 attacks on its retail sites to Shahid Kaveh (aka Cyber Aveng3rs and Cyber Isnaad Front), an Iranian cyber unit affiliated with the Islamic Revolutionary Guard Corps (IRGC).

In light of active exploitation, Federal Civilian Executive Branch (FCEB) agencies are being advised to apply the necessary fixes for all the flaws, except CVE-2026-133311 and CVE-2025-41450, by November 28, 2026. The remaining two vulnerabilities must be addressed by December 9, 2026.

CISA Warns of New Unpatched Danfoss AK-SM 8xxA Series Flaw

The development comes as CISA has warned of an unpatched critical flaw in Danfoss AK-SM 8xxA Series (CVE-2026-129713, CVSS score: 9.8 / 9.3) controllers that could be exploited to execute arbitrary code with webserver privileges.

“A stack-based buffer overflow in an unauthenticated CGI handler of the Danfoss AK-SM 8xxA Series controller allows remote attackers to send specially crafted HTTP/S POST requests, leading to memory corruption, webserver restart and hypothetically potential arbitrary code execution with webserver privileges,” CISA said. “Authentication is not required to exploit this vulnerability.”

Danfoss, which has issued an alert of its own, said the security flaw impacts versions 5.4.0 and earlier. A fix for the vulnerability is expected to be addressed in an upcoming software version (5.5.x). It also said it will remove the option that allows customers to disable “Strict mode” in the product.

Until the fixes are available, system administrators are advised to take the following actions –

  • Make sure remote access to the units is possible only through a secure VPN or in general over a protected network
  • Configure the units to Strict mode, which ensures higher security levels on the product
  • Recommend using strong passwords

CISA is also recommending that organizations minimize network exposure of such devices, place control system networks and remote devices behind firewalls, and isolate them from business networks.

“When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available,” CISA added. “Also recognize VPN is only as secure as the connected devices.”