Skip to content
EVoke Systems Charging Station Management System

EVoke Systems Charging Station Management System

  • by

View CSAF

Summary

Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks.

The following versions of EVoke Systems Charging Station Management System are affected:

CVSS Vendor Equipment Vulnerabilities
v3 9.4 EVoke Systems EVoke Systems Charging Station Management System Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials

Background

  • Critical Infrastructure Sectors: Energy, Transportation Systems
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: United States

Vulnerabilities

Expand All +

CVE-2026-40702

WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system.

View CVE Details


Affected Products

EVoke Systems Charging Station Management System

Vendor:
EVoke Systems

Product Version:
EVoke Systems EVoke CSMS: vers:all/*

Product Status:
known_affected

Relevant CWE: CWE-306 Missing Authentication for Critical Function


Metrics

CVE-2026-50176

The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks or brute-force attacks to gain unauthorized access.

View CVE Details


Affected Products

EVoke Systems Charging Station Management System

Vendor:
EVoke Systems

Product Version:
EVoke Systems EVoke CSMS: vers:all/*

Product Status:
known_affected

Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts


Metrics

CVE-2026-54479

The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.

View CVE Details


Affected Products

EVoke Systems Charging Station Management System

Vendor:
EVoke Systems

Product Version:
EVoke Systems EVoke CSMS: vers:all/*

Product Status:
known_affected

Relevant CWE: CWE-613 Insufficient Session Expiration


Metrics

CVE-2026-44622

Charging station authentication identifiers are publicly accessible via web-based mapping platforms.

View CVE Details


Affected Products

EVoke Systems Charging Station Management System

Vendor:
EVoke Systems

Product Version:
EVoke Systems EVoke CSMS: vers:all/*

Product Status:
known_affected

Relevant CWE: CWE-522 Insufficiently Protected Credentials


Metrics


Acknowledgments

  • Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA

Legal Notice and Terms of Use

This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).


Recommended Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.

Locate control system networks and remote devices behind firewalls and isolating them from business networks.

When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.


Revision History

  • Initial Release Date: 2026-06-25
Date Revision Summary
2026-06-25 1 Initial Publication

Legal Notice and Terms of Use

Source link